The Chemical Safety Board (CSB) is an independent federal agency in the United States that is in charge of investigating and reporting on accidents involving chemicals. The agency's board members are appointed by the president and confirmed by the Senate. The CSB...
Health, Safety, and the Environment (HSE) are important to keep in mind during all aspects of business operations. HSE involves ensuring the health of not only the human life working around hazardous environments, but also the environmental health that could possibly be affected...
Heat Exchangers are pieces of process equipment built and designed for maximum efficiency of heat transfer between two different machines or mediums. In most industrial processes, the loss of heat is very...
Process Hazards Analysis is a systematic method of identifying and evaluating the dangers involved with specific industrial processes in order to prevent or control potential hazards.[1,2,3] If properly conducted, it can be an effective tool for protecting...
A Process Safety Incident typically involves an unexpected mechanical integrity failure in a pipeline system or processing facility, often including a fire, explosion, rupture, or hazardous chemical leak. These incidents can be caused by a number factors including
The U.S. Chemical Safety Board (CSB) has released its final report into the June 13, 2013, explosion and fire at the Williams Olefins Plant in Geismar, Louisiana, concluding that process safety management program deficiencies during the 12 years...
Today the U.S. Chemical Safety Board (CSB) released a safety video into the fatal April 17, 2013, fire and explosion at the West Fertilizer Company in West, Texas, which resulted in 15 fatalities, more than 260 injuries, and widespread community...
The April 2010 fatal explosion and fire at the Tesoro refinery in Anacortes, Washington was caused by damage to the heat exchanger, a mechanism known as “high temperature hydrogen attack” or HTHA.
An ongoing investigation by the U.S. Chemical Safety Board (CSB) of the February 18, 2015 explosion at the ExxonMobil Refinery in Torrance, California, has uncovered multiple process safety management deficiencies that led to the accident and a...
The U.S. Chemical Safety Board has approved the final investigation report and video from the 2009 explosion and fire at caribbean petroleum terminal facility in Puerto Rico.
Video Description
The U.S. Chemical Safety Board (CSB) has released a safety video detailing its investigation of the June 13, 2013 explosion and fire at the Williams Olefins Plant in Geismar, Louisiana, which killed two workers and injured an additional 167. The deadly explosion and fire occurred when a heat exchanger containing flammable liquid propane violently ruptured.
The CSB’s newly released 12-minute safety video entitled, “Blocked In,” includes a 3D animation of the explosion and fire as well as interviews with CSB investigator Lauren Grim and Chairperson Vanessa Allen Sutherland. The video is based on the CSB’s final case study on the Williams incident.
Chairperson Sutherland said, “Our investigation on the explosion at Williams describes an ineffective process safety management program at the plant at the time of the incident. We urge other companies to incorporate our recommendations at their facilities and to assess the state of their cultures to promote safety at all organizational levels to prevent a similar accident.”
The CSB’s investigation found many process safety management program deficiencies at Williams, which set the stage for the incident. In particular, the CSB found that the heat exchanger that failed was completely isolated from its pressure relief valve.
In the video, Investigator Lauren Grim said, “When evaluating overpressure protection requirements for heat exchangers, engineers must think about how to manage potential scenarios, including unintentional hazards. In this case, simply having a pressure relief valve available could have prevented the explosion.”
The CSB investigation concluded that in the twelve years leading to the incident, a series of process safety management program deficiencies caused the heat exchanger to be unprotected from overpressure. As revealed in the investigation, during that time Management of Change Reviews, Pre-Startup Safety Reviews, and Process Hazard Analyses all failed to effectively identify and control the hazard. In addition, the CSB found that Williams failed to develop a written procedure for activities performed on the day of the incident, nor did the company have a routine maintenance schedule to prevent the operational heat exchanger from needing to be shut down for cleaning.
Finally, the video describes CSB’s recommendations made to the Williams Geismar plant which encourages similar companies to review and incorporate into their own facilities. These include:
Conduct safety culture assessments that involve workforce participation, and communicate the results in reports that recommend specific actions to address safety culture weaknesses
Develop a robust safety indicators tracking program that uses the data identified to drive continual safety improvement
And perform comprehensive process safety program assessments to thoroughly evaluate the effectiveness of the facility’s process safety programs.
“Managers must implement and then monitor safety programs and encourage a strong culture of safety to protect workers and the environment,” Chairperson Vanessa Allen Sutherland said.
About the Chemical Safety Board
The CSB is an independent federal agency charged with investigating serious chemical accidents. CSB investigations examine all aspects of chemical accidents, including physical causes such as equipment failure as well as inadequacies in regulations, industry standards, and safety management systems. The Board does not issue citations or fines but makes safety recommendations to companies, industry organizations, labor groups, and regulatory agencies such as OSHA and EPA.
For more information, please visit www.csb.govor contact Communications Manager Hillary Cohen at public@csb.gov or by phone at 202.446.8095.
Stay up to date with all things mechanical integrity and inspection.
Every Monday, we send out a newsletter containing the latest Inspectioneering articles, blog posts, industry news and events, and more.
Sign up below to start getting the newsletter in your inbox.
Comments and Discussion
Posted by Paul Guettler on February 2, 2017
Hello
Thanks for an informative article and...
Log in or register to read the rest of this comment.
Posted by Ahmed Alshammari on January 7, 2019
Robust Management of Change MOC practices are...
Log in or register to read the rest of this comment.
Add a Comment
Please log in or register to participate in comments and discussions.
Our proprietary furnace tube inspection system, FTIS is an ultrasonic inspection technology capable of rapid, automated fired heater coil inspection in refinery fired heaters. The data captured by our furnace tube inspection system is...
Comments and Discussion
Add a Comment
Please log in or register to participate in comments and discussions.