The U.S. Chemical Safety and Hazard Investigation Board (CSB) issued a new Safety Alert titled “Hazards Posed by Discharges from Emergency Pressure-Relief Systems.” The CSB’s alert highlights hazards identified with emergency pressure-relief systems from four CSB investigations. The alert advises facilities that while a discharge from emergency pressure-relief systems can help protect equipment from unexpected and undesired high-pressure events, it can also seriously harm or fatally injure workers and cause extensive damage to a facility if the discharge is not made to a safe location.
CSB Chairperson Steve Owens said, “All four of the incidents highlighted in the CSB’s safety alert underscore the importance of thoroughly evaluating emergency pressure-relief systems to ensure they discharge to a safe location where they will not harm people."
The four incidents highlighted in the CSB’s safety alert resulted in 19 deaths and 207 injuries. They include:
- On May 19, 2018, an ethylene release ignited, injuring 23 workers at the Kuraray America, Inc. ethylene and vinyl alcohol copolymer plant in Pasadena, Texas. The CSB’s animation of this event shows how this incident occurred during the startup of a chemical reactor system following a turnaround. High-pressure conditions developed inside the reactor and activated the reactor’s emergency pressure relief system, discharging flammable ethylene vapor horizontally into the ambient air in an area where a number of contractors were working.
- On November 15, 2014, approximately 24,000 pounds of highly toxic methyl mercaptan were released from an insecticide production unit at the E.I. du Pont de Nemours and Company (DuPont) chemical manufacturing facility in La Porte, Texas. The release fatally injured three operators and a shift supervisor inside a manufacturing building. During the early phases of the investigation, CSB investigators identified a number of worker safety issues—separate from the release scenario— including that several emergency pressure-relief systems at the facility were designed to discharge hazardous materials in a way that posed a risk to workers and the public.
- On May 4, 2009, highly flammable vapor released from a waste recycling process, ignited, and violently exploded at Veolia ES Technical Solutions, LLC, in West Carrollton, Ohio. The incident injured four employees, two seriously. Following the initial explosion, multiple other explosions occurred that t significantly damaged every structure on the site. Residences and businesses in the surrounding community also sustained considerable damage. The CSB concluded that uncontrolled venting from emergency pressure-relief valves to the atmosphere allowed tetrahydrofuran (THF) vapors to accumulate to explosive concentrations outside process equipment, and the vapors subsequently found an ignition source.
- On March 23, 2005, during the startup of an isomerization unit following a maintenance turnaround, a series of explosions occurred at the BP refinery in Texas City, Texas. The incident fatally injured 15 workers and injured an additional 180 workers. During the startup, a distillation tower flooded with flammable hydrocarbons and was over-pressurized. This activated the tower’s emergency pressure-relief system, which created a geyser-like release from the vent stack and formed a flammable vapor cloud that soon ignited and exploded.
CSB Board Member Catherine Sandoval said, “OSHA requires employers to provide a safe workplace. Effective and safe pressure relief systems help ensure safe operations of plants across the country.”
Using findings from these four incidents the CSB’s safety alert issues three key lessons for facilities.
- Follow existing good practice guidance.
- Evaluate whether the atmosphere is the appropriate discharge location or if there are safer alternatives.
- Ensure hazardous chemicals vented into the atmosphere discharge to a safe location.
The alert also calls on companies to evaluate and, when appropriate, update their emergency pressure relief systems to prevent future incidents and protect workers and surrounding communities from harm.
Board Member Sylvia Johnson said, “Our safety alert calls on companies to evaluate and, when appropriate, update their emergency pressure relief systems to prevent future incidents and protect workers and surrounding communities from harm.”
About the CSB
The CSB is an independent, non-regulatory federal agency whose mission is to drive chemical safety change through independent investigations to protect people and the environment. The agency’s board members are appointed by the President and confirmed by the Senate. CSB investigations look into all aspects of chemical incidents, including physical causes such as equipment failure as well as inadequacies in regulations, industry standards, and safety management systems. The CSB does not issue citations or fines but makes safety recommendations to companies, industry organizations, labor groups, and regulatory agencies such as OSHA and EPA. For more information, please visit www.csb.gov.
Comments and Discussion
There are no comments yet.
Add a Comment